SICF - PLANT CONFIGURATION

          FIX BED          
SYSTEM
100-200
kg/h

   MOVING BED   
SYSTEM
200-5000
kg/h
CHARGING    
Manual feeding standard option
Manual slag extraction standard  option
Automated feeding (e.g. TEE hover bed) option standard
Automated slag extraction  option standard
INCINERATION    
10% moisture content standard standard
< 3% Polymeric substances
such as Plastic, PVC, rubber etc.
standard standard
< 30% Polymeric substances option option
Liquid waste lance spray system option option
HEAT RECOVERY    
Steam boiler  no option
COOLING    
Environmental friendly Air Cooling System standard standard
FLUE GAS CLEANING    
Additive dosing system standard standard
Flue gas cleaning system standard standard
GAS MONITORING    
CEGM (Continuous Exhaust Gas Monitoring) System
Envisaged analyses could be Chlorides (Hcl, Cl2), NOx,
SO2 as SOx, Carbons as TOC, CO and TSP (total
suspended particles) etc.
 no option
PLANT CONTROL    
Control box for indoor erection incl. main switch,
redundant emergency stop as well as all necessary
fuses, contacts, relays and clamps, key switch for
Start-up, completely cabled.
standard standard
Visualisation
All relevant process parameters and data are monitored
and stored on a PC visualisation system.
 no option

Each incineration system will be adapted to the project requirements.

Download as PDF
 

These documents (PDF Files) may also interest you:

stationary incinerators with a capacity of 100-200 kg/h

  Stationary Incinerator
SICF100-200

Fixed Bed Plant
Moving Bed Plant
Capacity 100-200 kg/h
 

stationary incinerators with a capacity of 300-500 kg/h

  Stationary Incinerator
SICF300-500

Moving Bed Plant
Hover bed technology
Capacity 300-500 kg/h

stationary incinerators with a capacity of 1000-5000 kg/h

  Stationary Incinerator
SICF1000-5000

Moving Bed Plant
Hover bed technology
Capacity 1000-5000 kg/h
 

transportable incinerators

  Transportable Incinerators
TIU 8G

transportable incinerators - disease control units

  Transportable Disease Control Units
DCU 8G
 

comparison TIU and MIU - Zanni + Partner Ltd

  Comparison
TIU / MIU units

Environmental Protection

 

Environmental Protection

 

Thermal Processes - Thermal Environmental Engineering - TEE

  Thermal Processes -
Thermal Environmental Engineering